<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-30 19-31-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.6 kHz -72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 74 kHz 10140 0,2170
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,9 dBr 8,36 dBr 8,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 19:31, 30.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (59 dBuV) Max at: 74 kHz MIN: 17 kHz % above 76 kHz: 0,2170 Acquired: 2025/04/30 19:30:36 Total samples: 10140 Equivalent time: 0:08:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,8 dBr MIN: 7,9 dBr AVE: 8,36 dBr % above 10,2 dBr: 0,0 Last value: 8,7 dBr (2025/04/30 19:30:36) Station: 96.90 MHz, signal: 5/5 (59 dBuV) 19:24 19:25 19:26 19:27 19:28 19:29 19:30 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality